Blog

How to fix the Oracle error PLS-00660: SELF parameter of constructor method must be IN OUT?

In this post, you’ll learn more about the Oracle ErrorPLS-00660: SELF parameter of constructor method must be IN OUT with the details on why you receive this error and the possible solution to fix it. Oracle Error Description PLS-00660: SELF parameter of constructor method must be IN OUT Reason for the Error PLS-00660: SELF parameter of constructor method must be IN OUT The mode of…

How to fix the Oracle error OCI-31040: Property string: XML type (string) not compatible with internal memory type (string)?

In this post, you’ll learn more about the Oracle ErrorOCI-31040: Property string: XML type (string) not compatible with internal memory type (string) with the details on why you receive this error and the possible solution to fix it. Oracle Error Description OCI-31040: Property string: XML type (string) not compatible with internal memory type (string) Reason for the Error OCI-31040: Property string: XML type (string) not…

How to fix the Oracle error ORA-01312: Specified table/column does not exist?

In this post, you’ll learn more about the Oracle ErrorORA-01312: Specified table/column does not exist with the details on why you receive this error and the possible solution to fix it. Oracle Error Description ORA-01312: Specified table/column does not exist Reason for the Error ORA-01312: Specified table/column does not exist The table/column specified in the lcr_mine call does not exist at the the specified SCN….

SQL Server Error Code – 25635 an attempt was made to add an asynchrono

In this blog post, you’ll learn more about the SQL Server Error Code 25635 and the error message description that is shown SQL Server Error Code 25635 SQL Server Error Description for the Code :25635 An attempt was made to add an asynchronous target to a session with a maximum memory of 0. For asynchronous targets to be added to a session, the session must…

SQL Server Error Code – 6274 alter assembly failed because the serial

In this blog post, you’ll learn more about the SQL Server Error Code 6274 and the error message description that is shown SQL Server Error Code 6274 SQL Server Error Description for the Code :6274 ALTER ASSEMBLY failed because the serialization format of type ‘%s’ would change in the updated assembly. Persisted types are not allowed to change serialization formats.

InterSystems IRIS General Error Code – 16000

In this post, you’ll learn about the General error code 16000 in InterSystems IRIS database the reason why you are receiving the error message when using the InterSystems IRIS data platform Error Code : 16000 Reason for the Error code 16000 in InterSystems IRIS DBMS Line: ‘%1’ Offset: ‘%2’.